logo

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V

5
MOQ
1USD
Price
BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V
Features Gallery Product Description Chat Now
Features
Specifications
Model No.: M30.1.2V
DC Input Voltage: 40~60Vdc
Current(A): ≤0.5A
Power(W): Less Than 20W
Rs485: Default (Modbus Protocol RTU)
TCP/IP: Default
SNMP: Customized
Baud Rat: 9600 Bit/s
Highlight:

40~60Vdc Rectifier System Monitor Controller

,

BWT Rectifier System Monitor Controller

,

M30.1.2V Rectifier System Monitor Controller

Basic Infomation
Place of Origin: CHINA
Brand Name: BWitt
Model Number: M30.1.2V
Payment & Shipping Terms
Packaging Details: 27*32*10.5
Delivery Time: 7-15days
Payment Terms: T/T
Supply Ability: lakh
Product Description

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 0

The M30 is a compactsite monitoring module that captures module voltage, current, and alarm information, and adjusts module current limit, overvoltage point, and control module power on/off. M30 provides RS485 communication interface (1 way north, 2 way south), rectifier module communication interface (support RS485 and CAN), sensor interface (ambient temperature and humidity, battery temperature), 6 input dry contact interface (can Associated access control, flooding, smoke, lightning protection, oil machine, temperature control failure, battery out of position and standby DI), 1 channel three-phase AC detection port, 6 output dry contact interface, 9 channel current detection, 2 channel battery melting Wire and 1 total load fuse detection, 5 levels power-down management, 9-channel user power record, battery management, system energy saving, etc., to meet the user's demand for power monitoring functions. The M30 supports the sound and light alarm, the access of the smart device, the dry contact upload, the RS485 upload, and the TCP/IP upload mode. The environment information and alarm information will be reported.

 

Specification

Technical
DC Input Voltage (V) 40~60Vdc
  Current(A) ≤0.5A
  Power(W) Less than 20W
Communication Interface Rs485 Default (Modbus Protocol RTU)
  TCP/IP Default
  SNMP Customized
  6 Dry Contact AC Power Failure,AC Input Fault ,DC Output Fault ,Battery Over Voltage,DI Dry contact,Rectifier module output Over Voltage,Rectifier module output Under Voltage,Rectifier Module Fault,Rectifier Module Communication Fault,Rectifier Module Current Limiting,Rectifier module current non-equalize,Rectifier module Protection,Battery Power off ,Load Fuse,Battery Fuse,Battery Connect Fail
  Signal Input 1* Battery Temp,1*Ambient Temp,1*Air Conditioning ,. 1*Smoke Alarm.,1*Flooding Alarm.,1*Access Alarm.,1*Surge arrest,1* Fan,1*generator
  Baud Rate 9600 Bit/s
Storage Capacity Historical Alarm Records Up to 1000 Units
Display Mode   LC

 

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 1

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 2

 

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 3

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 4BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 5

BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 6BWT Monitor Controller Of Rectifier System 40~60Vdc M30.1.2V 7

Recommended Products
Get in touch with us
Tel : 13011182266
Fax : 86-010-80303109
Characters Remaining(20/3000)