Mean Well Portable Type Metal Enclosure Charger NPB-120-12 NPB-120-24 NPB-120-48
New models:
NPB-120 / NPB-240 / NPB-360
Old models:
PA-120 / PB-120
Standard type highly reliable wide voltage range charger
Metal enclosure for better heat dissipation , leading lower touch temperature
Easy and flexible adjustment:
‧ Charging voltage adjustable through front panel (10.5~15.2V, 21~30.4V, 42~60.8V)
‧ Charging current adjustable through panel (50~100% of rated current)
‧ 2 or 3 stage selectable by DIP S.W. on front panel
Protections: Short circuit, over voltage, over temperature, battery reverse polarity
Comply with UL/EN62368-1 and IEC60335-1/2-29 dual certifications
Multiple DC output plugs selectable: Anderson, terminal block and 4 pin power pin
Technical
MODEL | NPB-120-12 | NPB-120-24 | NPB-120-48 | ||
=XLR, AD1, TB | |||||
OUTPUT |
BOOST CHARGE VOLTAGE(Vboost)(default) | 14.4V | 28.8V | 57.6V | |
FLOAT CHARGE VOLTAGE(Vfloat)(default) | 13.8V | 27.6V | 55.2V | ||
VOLTAGE ADJUSTABLE RANGE | 10.5 ~ 15.2V | 21 ~ 30.4V | 42 ~ 60.8V | ||
OUTPUT CURRENT(Typ.) Note.5 | 6.8A | 4A | 2A | ||
CURRENT ADJUSTABLE RANGE | 50% ~ 100% | ||||
MAX. POWER Note.3 | 103.4W | 121.6W | 121.6W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4 | 20 ~ 90AH | 15 ~ 50AH | 7 ~ 25AH | ||
INPUT |
VOLTAGE RANGE Note.5 | 90 ~ 264VAC 127 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.92/230VAC@12V,PF>0.93/230VAC@24/48V at full load | ||||
EFFICIENCY (Typ.) |
XLR | 86.5% | 89% | 90.5% | |
AD1 | 86.5% | 89% | 90.5% | ||
TB | 87% | 89.5% | 90.5% | ||
AC CURRENT (Typ.) | 1.5A/115VAC 0.8A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 55A at 230VAC | ||||
PROTECTION |
SHORT CIRCUIT Note.6 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | |||
OVER VOLTAGE | 16 ~ 20V | 32 ~ 40V | 64 ~ 75V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | |||||
REVERSE POLARITY | By internal fuse open | ||||
OVER TEMPERATURE | Hiccup mode, recovers automatically after temperature goes down | ||||
FUNCTION | CHARGING CURVE | 2 or 3 stage adjustable by DIP S.W | |||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 45℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS |
CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, AS/NZS60335-1/2-29, EAC TP TC 004 approved |
|||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||
Conducted | BS EN/EN55032 (CISPR32),BS EN/EN55014-1 | Class B | |||
Radiated | BS EN/EN55032 (CISPR32),BS EN/EN55014-1 | Class B | |||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||
EMC IMMUNITY |
BS EN/EN55014-2,BS EN/EN55024,BS EN/EN55035 | ||||
Parameter | Standard | Test Level / Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 2, 3V/m | |||
EFT / Burst | BS EN/EN61000-4-4 | Level 2, 1KV | |||
Surge | BS EN/EN61000-4-5 | Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth | |||
Conducted | BS EN/EN61000-4-6 | Level 2, 3Vrms | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 1, 1A/m | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
|||
OTHERS |
MTBF | 1895.4K hrs min. Telcordia TR/SR-332 (Bellcore) ; 225.8K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 182.7*96*49mm (L*W*H) | ||||
PACKING | 1.3Kg; 10pcs/ 14Kg / 1.13CUFT | ||||
NOTE |
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3. Refer to derating curve. 4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 7. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.