Part No.: 241115.105
BrandA: Eltek
Model Name: Flatpack2 48/2000HE
Effciency: 96.5%
Application: Telecom And More
Input Voltage: 85 - 305 VAC
Output Voltage: 300 - 400 VDC
Output Power: 2000 W
Current: 62,5 ADC
Weight: 2 Kg
Highlight:

Rectifier Module 241115.105

,

96.5% flatpack2 48v 2000w

,

flatpack2 48v 2000w 241115.105

Basic Infomation
Place of Origin: CN
Brand Name: Eltek
Certification: CE
Model Number: 241115.105
Payment & Shipping Terms
Packaging Details: cartons
Delivery Time: 8-10 weeks
Payment Terms: L/C,T/T
Supply Ability: 3000 pieces per month
Product Description


96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 0


Eltek Rectifier Module Flatpack2 48/2000HE 48V 2000W high efficiency (Part No. 241115.105)



Flatpack2 48/2000 HE

The combination of innovative design, efficiency and reliability makes the Flatpack2 HE stand out.

Increasing network speed demands flexible and expandable DC power solutions. The Flatpack2 HE rectifiers are your key building blocks for future needs.


The most reliable High Efficieny rectifier in the industry!

With an efficiency up to 96.5%, the losses have been reduced by 50% compared to the current industry standard. In a global perspective, considering the high energy consumption in the telecom industry, this technology breakthrough is not only reducing operational cost for the operators, but it can also have a significant environmental impact.


Key features

  • Power dense, up to 33 W/inch3
  • High efficiency
  • Proven reliability
  • Application flexibility 2kW-3MW
  • Global compliance
  • Patented HE technology




Parameters :
 


Model 48V / 2000W HE 48V / 3000W HE
Part number 241115.105 241119.105
INPUT DATA
Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC 176 - 277 VAC
Voltage (range) 85 - 300 VAC / 85 - 275 VDC 85 - 305 VAC
Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz 45 - 66 Hz
Current (maximum) @ nominal input, full load 11.6 ARMS 19.2 ARMS


Protection

Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC

Fuse in both lines Varistor for transient protection

Disconnect above 305 VAC

OUTPUT DATA
Voltage (default) 53.5 VDC
Voltage (adjustable range) 43.5 - 57.6 VDC 43.2 - 582) VDC
Power (maximum) 2000 W 3000 W
Power @ 85 VAC 850 W 1380 W
Current (maximum) @ nominal input, full load 41.7 A 62.5 A
Ripple, 30MHz bandwidth < 100 mVpp < 150 mVpp
Psophometric noise < 2 mVRMS < 2 mVRMS
Static Voltage regulation ±0.5% for 10 - 100% load
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting
OTHER SPECIFICATIONS
Efficiency @ nominal input 96 %


Isolation

4.0 kVDC - input to output, 2.5 kVDC - input to earth, 710 VDC - output to earth 5.0 kVDC - input to output, 2.5 kVDC - input to earth, 710 VDC - output to earth
Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure
Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage
Normal (module running): Green LED 'on'
MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 °C) >300 000 (@ Tambient : 25 °C)
Operating temperature -40 to +75°C (-40 to +167°F)4), humidity 5 - 95% RH non-condensing
Temperature de-rating >55°C (131°F), 1200W @ 75°C (167°F) >55°C3) (131°F), 2100W @ 75°C (167°F)4)
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs)
DESIGN STANDARDS
Electrical safety EN 62368-1:2020+A11:2020, IEC 62368-1:2018, IEC 60950-1:2005+A2:2013 UL 62368-1:2019 , CSA C22.2 No.62368-1:2019
EMC EN 61000-6-1:2019, -6-2:2019, -6-3:2007+A1:2011+A2:2012+AC:2012, -6-4:2019, EN 61000-3-2:2019, ETSI EN 300 386 V.2.2.0:2020, Telcordia NEBS GR1089 CORE
Marine DNVGL-CG-0339 -



Environment

ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE)

Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised

1) power derating, maximum 1000W @ 230Vac 16 2/3 Hz

2) 57.6V for HW revision ≤ 5

3) 3kW: from HW revision 6: shutdown at 95°C with de-rating to ~1000W

 

   

                                           
 
 
96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 1
 

96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 2


96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 396.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 4
 
96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 5
 
 
Solutions

As experts in the telecommunications field, we deliver a complete solution for telecom companies both within and outside China. Our site survey is conducted with the utmost precision, using advanced tools and techniques to gather accurate data. Based on this information, we propose a highly professional plan that is customized to the customer's unique requirements. Our technical support team is comprised of industry - leading professionals who can resolve any technical issues efficiently, and our maintenance services are designed to ensure the long - term performance and reliability of the telecommunications systems. We have a network of trusted partners around the world who share our commitment to excellence.


 
FAQ :

1.Q: How do you monitor and control product quality?

A: We have a sophisticated quality control system in place. Before products are dispatched, we subject them to a series of tests that mimic real - world usage. We conduct load, full - load, and current sharing tests to identify and eliminate any potential quality issues. This way, we can ensure that the products you receive are of the highest quality and perform reliably.


2.Q: What's the minimum order quantity you accept?

A: We don't have a minimum order quantity. Whether you need one item for personal use or a large quantity for your business, we're happy to fulfill your order. However, the price and delivery schedule may vary depending on the quantity ordered.


3.Q: Can you tell me about your company's background and capabilities?

A: I'd be happy to! I'll send you our company's detailed introduction shortly. This document will give you an in - depth look at our company's history, our technological capabilities, our manufacturing processes, and our market position. It will help you understand why we're a trusted provider in the industry.


4.Q: What are the competitive advantages of your company?

A: Our company offers several key advantages. We have a large and well - managed inventory, which allows us to provide a stable supply for your future orders. We also offer a high level of flexibility in our services. We can customize our solutions based on your specific needs, ensuring that you get the products and services that are right for you.


5.Q: Is it possible to request samples and get a price breakdown?

A: Yes, you can request samples. The samples are priced according to our regular bulk rates, and you'll need to cover the shipping cost. Once you've requested the samples, we'll send you a detailed price breakdown so you know exactly what you're paying for.


 
96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 6
 
 
 
 96.5% Telecom Rectifier Module Flatpack2 48v 2000w 241115.105 7
 
 
 

Recommended Products
Get in touch with us
Contact Person : Lee
Tel : 13011182266
Fax : 86-010-80303109
Characters Remaining(20/3000)