Powering IT facilities, manufacturing plants, telecom networks, power utilities, metro systems and railways —
that is what Ding Ding Future Technology Co., Ltd. does best. Drawing on solid, field-proven experience in solar energy,
data centers and emergency power, we assemble complete turnkey AC/DC solutions that remove the hassle from
procurement and keep every stage of execution on track. We work as your committed partner, prepared to handle whatever a project throws at us.
Core Products
Engineered for critical telecom infrastructure, this 19-inch 2RU inverter converts 125VDC battery bank power into 220VAC 60Hz pure sine wave output. Delivering 6KVA (4800W) of continuous power, it features 4 standard IEC C13 sockets for seamless connectivity to radios, routers, and BTS controllers. Equipped with an intelligent LCD display, RS485/SNMP communication, and a built-in ATS bypass, it ensures 24/7 uptime even during grid failures. The robust metal chassis fits standard racks, making it the ultimate DC-AC solution for unattended base stations.
Use Cases:
Parameters:
|
Parameter |
125/220-3KVA |
125/220-2KVA |
125/220-1KVA |
|---|---|---|---|
|
INPUT |
|||
|
Battery Input Voltage |
100~150Vdc |
- |
- |
|
Battery Voltage Range |
125Vdc |
- |
- |
|
DC Input Current |
30A Max |
20A Max |
10A Max |
|
Bypass Input Voltage |
220Vac Normal |
- |
- |
|
Bypass Voltage Range |
170~270Vac |
- |
- |
|
AC Input Frequency |
50Hz/60Hz |
- |
- |
|
Frequency Range |
43~67Hz |
- |
- |
|
PF |
>0.8 |
- |
- |
|
OUTPUT |
|||
|
Output Capacity |
3000VA |
2000VA |
1000VA |
|
Rated Output Capacity |
2400W |
1600W |
800W |
|
Rated output Voltage |
220VAC (Inverter Mode) |
- |
- |
|
Rated Output Current |
10.9A |
7.27A |
3.63A |
|
Output Voltage Range |
220Vac(Tolerance ±1.5% @Inverter Mode) |
- |
- |
|
Output Efficiency |
≥85% (Inverter Mode) |
- |
- |
|
Output Frequency |
50Hz/60Hz |
- |
- |
|
Output Wave |
Pure sine wave |
- |
- |
|
THD |
≤3% (Line Load) |
- |
- |
|
Switch Time (By pass to Inverter mode) |
≤5ms (With Load) |
- |
- |
|
PROTECTIVE FEATURE |
|||
|
AC Under Voltage Switch Protection |
≤176Vac (Backlash voltage≥10Vac) |
- |
- |
|
AC over Voltage Switch protection |
≥264AC |
- |
- |
|
Over-Temperature |
Yes (Auto Switch) |
- |
- |
|
Battery under voltage protection point |
≤95VDC |
- |
- |
|
Battery Low-voltage alarm |
90VDC±0.5 |
- |
- |
|
Battery overvoltage protection point |
≥155VDC |
- |
- |
|
Battery overvoltage recovery point |
≤150VDC |
- |
- |
|
OUTPUT OVER CURRENT PROTECTION |
|||
|
Over Load Capacity |
Continue working 60s @ 101%<load<120% |
- |
- |
|
Over Load Capacity |
Continue working 10s @ 121%<Load<150% |
- |
- |
|
Over Temp. Protection |
Yes |
- |
- |
|
short circuit Protection |
Yes (Don't test under AC Connect) |
- |
- |
|
Reverse connection protection |
Yes |
- |
- |
|
Output OVP |
≥264VAC(Inverter Mode) |
- |
- |
|
Output low voltage alarm |
≤176VAC (Inverter Mode) |
- |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service
in and out of China. We have a competent team and a network of trusted Partners around the world.
FAQ :
Q: Can this inverter run on a 125VDC telecom battery bank?
A: Yes, it is specifically designed for 125VDC nominal input (compatible with lead-acid or lithium DC screens) and outputs stable 220VAC 60Hz.
Q: Does it support remote monitoring?
A: Yes, standard RS485 and optional SNMP allow real-time monitoring of voltage, load, and status via NMS.
Q: What happens if the DC fails?
A: The built-in Auto Transfer Switch (ATS) seamlessly switches to AC mains bypass (220VAC IN) to keep the load powered.